Type of Chargers

 

    Every Public Charging Station (PCS) will have the following infrastructure:

    i. An exclusive transformer with all related substation equipment including safety appliance, if required.

    ii. Electric line/cables with associated equipment including line termination etc.

    iii. Appropriate civil works

    iv. Appropriate cabling & electrical works ensuring safety

    v. Adequate space for Charging and entry/exit of vehicles.

    vi. Public Charging Station shall have, two or more chargers combination of chargers (as mentioned in para 8) from the table given below:

Sr. No.

Charger Type

Charger Connectors*

Rated Output Voltage (V)

No. of Connector Guns (CG)

Charging Vehicle type (W=wheeler)

1

Fast

Combined Charging System (CCS) (min 50 KW)

200-750 or higher

1 CG

4W

2

Fast

CHArge de Move (CHAdeMO) (min 50 KW)

200-500 or higher

1 CG

4W

3

Fast

Type-2 AC min 22 KW)

380-415

1 CG

4W, 3W, 2W

4

Fast

CCS (min 100 KW)

200-750  or higher

1 CG

4W, long range EVs and/or heavy duty EVs

5

Fast

CHAdeMO min 100 KW)

200-750  or higher

1 CG

4W, long range EVs and/or heavy duty EVs

6

Fast

CCS &CHAdeMO (min 100 KW)

200-750  or higher

2 CG

4W, long range EVs and/or heavy duty EVs

7

Slow / Moderate

Bharat DC-001 (15 KW)

48

1 CG

4W, 3W, 2W

8

Slow / Moderate

Bharat DC-001 (15 KW)

72 or higher

1 CG

4W

9

Slow / Moderate

Bharat AC-001 (10 KW)

230

3 CG of 3.3 KW each

4W, 3W, 2W

* In addition, any other fast/slow/moderate charger as per approved DST/BIS standards whenever notified.
   Note: Type-2 AC (min 22 KW) is capable of Charging e-2W/3W with the provision of an adapter.

 

Note: This site best viewed in Google Chrome